Hydraulics · pre-development 2014–2015
Firmware for hydraulic valves with separate metering edges
Firmware for an HCS12X control unit with separate meter-in and meter-out edges – flow, pressure and speed control, developed model-based and verified on the test bench.
- HCS12X
- SimulationX
- Model-based development
- Control engineering
- Cosmic Compiler
- FlexPro
- SlickEdit
Challenge
In hydraulics, many applications today each use their own specialised valve. A novel valve with separate meter-in and meter-out control edges was meant to change that. Our task in pre-development: firmware for an HCS12X embedded system that makes the potential of this design usable.
Approach
- Model-based simulation of the valve with SimulationX
- A computational model of the control edge runs directly in the control unit
- Several control modes: flow-controlled, pressure-controlled and speed-controlled
- The controlled variable is pressure, complemented by knowledge of piston areas and cylinder volumes
- Around six months of empirical test bench work in Hamburg to develop and verify the algorithms; measurement data analysed with FlexPro
- Multi-level fault memory and modular connection to various OEM systems
What separate metering edges make possible
- Common parts: one valve for several applications instead of many specialised valves
- New control functions: meter-in and meter-out are decoupled, so the valve can behave differently depending on pressure or flow
- Better metering, less energy: finer metering and less pump work
- Fewer valves, distributed systems: multiplexing reduces the number of valves; several control units work together on a bus
Outcome
Pre-development ran from 2014 to 2015. The result was a working system that was demonstrated to manufacturers of mobile machinery, including forestry and materials handling equipment. Our part was the pre-development of the firmware.
More about our control and embedded software.
Frequently asked questions
What are separate metering edges?
The meter-in and meter-out of a hydraulic valve are controlled separately instead of via a shared control edge. This reduces throttling losses and enables new open- and closed-loop control functions.
What was SimulationX used for?
For the model-based simulation of the valve. In addition, a computational model of the control edge ran directly in the control unit, and the algorithms were verified in around six months of test bench work.